Datasheets and attachments

Description

GW Instek APS-7100 Programmable AC power source, 1000 VA

The GW Instek APS-7000 series AC power sources are fully programmable to simulate different power outputs. The APS-7000 series has nine measurement functions.

Features:

  • Display: 4.3" LCD
  • Measurements: Voltage, Current, Power, Frequency, Power Factor, Crest Factor,
  • Apparent Power, Ipeak, Ipk hold
  • Surge/Dip Control Mode
  • Frequency: 45-500 Hz (standard), 45-999.9 Hz (Opt)
  • Protection: OVP/OCP/OTP
  • Simulate mode, sequence mode, program mode
  • Ramp control function
  • ARB (Function Waveform) mode
  • Standard Interface: USB/LAN

Applications:

  • Ideal for various power supply manufacturers
  • Development of electronic components and testing applications
  • Incoming quality control and R&D applications
  • Small AC current measurement applications
Technical information
APS-7050 APS-7100
Power rating 500 VA 1000 VA
Output voltage 0-310 Vrms 0-310 Vrms
Output frequency 45-500 Hz 45-500 Hz
Maximum current (rms) 4.2 A (0-155 Vrms) / 2.1 A (0-310 Vrms) 8.4 A (0-155 Vrms) / 4.2 A (0-310 Vrms)
Maximum current (peak) 16.8 A (0-155 Vrms) / 8.4 A (0-310 Vrms) 33.6 A (0-155 Vrms) / 16.8 A (0-310 Vrms)
OPT. APS-003 (rms) 0-600 Vrms 1.05 A at 480 V 2.1 A at 480 V
OPT. APS-003 (peak) 0-600 Vrms 4.2 A 8.4 A
Total Harmonic Distoration (THD)

≤0.5 % at 45-500 Hz (Resistive Load)

Crest factor

≥4

Line regulation 0.1 % (% of full scale)
Load regulation 0.5 % (% of full scale)
Response time <100 µs
General
Remote output Signal Pass, fail, test-in process, trigger in, trigger out, OUT ON/OFF
Sync output signal Output signal 10 V, BNC type
Number of preset 10 (0-9 numeric keys)
Protection OCP, OPP, OHP and alarm
Dimensions (WxHxD) / Weight 430 x 88 x 400 mm / approx. 24 kg 430 x 88 x 560 mm / approx. 38 kg
Sequence/Simulation/Function
Number of memories 10 (0-9 numeric keys)
Number of steps 255 max. (for each sequence)
Step time setting 0.01-99.99s
Operation within step Constant/keep/linear sweep
Parameters Output range, frequency, waveform (sine waveform only), on phase, off phase, term jump count (0-255)
Sequence control Start, stop, hold, continue, branch 1, branch 2

For more information see the datasheets.

Description
Technical information

GW Instek APS-7100 Programmable AC power source, 1000 VA

The GW Instek APS-7000 series AC power sources are fully programmable to simulate different power outputs. The APS-7000 series has nine measurement functions.

Features:

  • Display: 4.3" LCD
  • Measurements: Voltage, Current, Power, Frequency, Power Factor, Crest Factor,
  • Apparent Power, Ipeak, Ipk hold
  • Surge/Dip Control Mode
  • Frequency: 45-500 Hz (standard), 45-999.9 Hz (Opt)
  • Protection: OVP/OCP/OTP
  • Simulate mode, sequence mode, program mode
  • Ramp control function
  • ARB (Function Waveform) mode
  • Standard Interface: USB/LAN

Applications:

  • Ideal for various power supply manufacturers
  • Development of electronic components and testing applications
  • Incoming quality control and R&D applications
  • Small AC current measurement applications
APS-7050 APS-7100
Power rating 500 VA 1000 VA
Output voltage 0-310 Vrms 0-310 Vrms
Output frequency 45-500 Hz 45-500 Hz
Maximum current (rms) 4.2 A (0-155 Vrms) / 2.1 A (0-310 Vrms) 8.4 A (0-155 Vrms) / 4.2 A (0-310 Vrms)
Maximum current (peak) 16.8 A (0-155 Vrms) / 8.4 A (0-310 Vrms) 33.6 A (0-155 Vrms) / 16.8 A (0-310 Vrms)
OPT. APS-003 (rms) 0-600 Vrms 1.05 A at 480 V 2.1 A at 480 V
OPT. APS-003 (peak) 0-600 Vrms 4.2 A 8.4 A
Total Harmonic Distoration (THD)

≤0.5 % at 45-500 Hz (Resistive Load)

Crest factor

≥4

Line regulation 0.1 % (% of full scale)
Load regulation 0.5 % (% of full scale)
Response time <100 µs
General
Remote output Signal Pass, fail, test-in process, trigger in, trigger out, OUT ON/OFF
Sync output signal Output signal 10 V, BNC type
Number of preset 10 (0-9 numeric keys)
Protection OCP, OPP, OHP and alarm
Dimensions (WxHxD) / Weight 430 x 88 x 400 mm / approx. 24 kg 430 x 88 x 560 mm / approx. 38 kg
Sequence/Simulation/Function
Number of memories 10 (0-9 numeric keys)
Number of steps 255 max. (for each sequence)
Step time setting 0.01-99.99s
Operation within step Constant/keep/linear sweep
Parameters Output range, frequency, waveform (sine waveform only), on phase, off phase, term jump count (0-255)
Sequence control Start, stop, hold, continue, branch 1, branch 2