5 MHz Precision LCR Meter

In stock
SKU: LCR-8205
Technical information & projects
Ari Vahanen [email protected]
+358102891276
Weight 3.3 kg
Unit of measure pcs
Product number LCR-8205
Part number LCR-8205
Brand Name GW Instek

Vantaa

By order

Delivery time: 14 business days

€0.00 €0.00 Excl. Tax Incl. Tax
Description

GW Instek LCR-8205 High-frequency LCR meter, 10 Hz...5 MHz

The GW Instek's LCR-8200 series has four models (LCR-8205, LCR-8210, LCR-8220, and LCR-8230) and the maximum frequency up to 30 MHz. The LCR-8200 series high-frequency LCR meter has a full range of standard interfaces such as USB device, RS-232C, handler and GPIB. The measurement results can be presented numerically or graphically depending on the selected measurement mode. The LCR-8200 series helps users respond to the test requirements of passive components in R&D, engineering, and production.

Features:

  • Test frequency range: 10 Hz...30 MHz
  • Display: 7" LCD color
  • Basic accuracy: 0.08 %
  • 17 selectable measurement parameters -> four of them can be displayed simultaneously
  • Two curves sweep mode
  • Internal DC bias voltage ±12 V
  • USB storage available
  • ALC function available
  • Universal power input
  • Standard interfaces: LAN, USB host/device, RS-232C, GPIB and handler

For more information, see the datasheet.

Technical information
  LCR-8205 LCR-8210 LCR-8220 LCR-8230
Test frequency DC, 10 Hz...5 MHz;
6 digits, ±0.0007%
DC, 10 Hz...10 MHz;
6 digits, ±0.0007%
DC, 10 Hz...20 MHz;
6 digits, ±0.0007%
DC, 10 Hz...30 MHz;
6 digits, ±0.0007%
Output impedance 25 Ω / 100 Ω selectable
Basic accuracy ±0.08 %
Test speed MAX: 2.5 ms (>10 kHz), FAST: 50 ms (>20 Hz), MEDIUM: 100 ms, SLOW: 300 ms, SLOW2: 600 ms
Test signal level
    AC Voltage 10 mV...2 Vrms (freq. ≤ 1 MHz), 10 mV...1 Vrms (freq. > 1 MHz or freq. ≤ 1 MHz and RO=25 Ω)
    AC Current 100 µA...20 mArms (RO=100 Ω), 400 µA...40 mArms (RO=25 Ω)
    DCR Voltage 1 VDC (40 mA max.)
Measurement parameters Maximum four parameters can be measured and displayed at the same time
Impedance (Z), Inductance (Ls / Lp), Capacitance (Cs / Cp), AC Resistance (Rs / Rp), Quality Factor (Q),
Dissipation Factor (D), Admittance (Y), Conductance (G), Reactance (X), Phase Angle ( d / r), θ θ
Susceptance (B), DC Resistance (Rdc)
List measurement
    Listed steps  15
    Listed parameters  Freq/VAC/I AC/DC Bias/Comp/BIN
    Trigger  AUTO, REPEAT, SINGLE
Sweep measurement
    Swept graphical Two of measurement parameters
    Swept parameters Freq/VAC/I AC, Keep Trace
Other functions
    Auto level control (ALC) Standard
    DC Bias 0...±12 V
    Handler PASS, FAIL and OK, NG or BIN 1-9
Other features
    Correction Open/Short/HF Load/Load
    V/I monitor VAC, I AC, VDC, I DC
    Comparator Value, Δ, Δ%
    Buzzer OFF, pass, fail
    Average 1 to 64
Display 7" LCD color display (800 x 480)
Interface USB/GPIB/LAN/RS-232/Handler/USB Host/TRIGGER Input
Power source AC 100 V...240 V, 50/60 Hz / Consumption: 65 VA (max.)
Dimensions (WxHxD)
and weight
346 x 145 x 335 mm / Approx. 3.3 kg
Description
Technical information

GW Instek LCR-8205 High-frequency LCR meter, 10 Hz...5 MHz

The GW Instek's LCR-8200 series has four models (LCR-8205, LCR-8210, LCR-8220, and LCR-8230) and the maximum frequency up to 30 MHz. The LCR-8200 series high-frequency LCR meter has a full range of standard interfaces such as USB device, RS-232C, handler and GPIB. The measurement results can be presented numerically or graphically depending on the selected measurement mode. The LCR-8200 series helps users respond to the test requirements of passive components in R&D, engineering, and production.

Features:

  • Test frequency range: 10 Hz...30 MHz
  • Display: 7" LCD color
  • Basic accuracy: 0.08 %
  • 17 selectable measurement parameters -> four of them can be displayed simultaneously
  • Two curves sweep mode
  • Internal DC bias voltage ±12 V
  • USB storage available
  • ALC function available
  • Universal power input
  • Standard interfaces: LAN, USB host/device, RS-232C, GPIB and handler

For more information, see the datasheet.

  LCR-8205 LCR-8210 LCR-8220 LCR-8230
Test frequency DC, 10 Hz...5 MHz;
6 digits, ±0.0007%
DC, 10 Hz...10 MHz;
6 digits, ±0.0007%
DC, 10 Hz...20 MHz;
6 digits, ±0.0007%
DC, 10 Hz...30 MHz;
6 digits, ±0.0007%
Output impedance 25 Ω / 100 Ω selectable
Basic accuracy ±0.08 %
Test speed MAX: 2.5 ms (>10 kHz), FAST: 50 ms (>20 Hz), MEDIUM: 100 ms, SLOW: 300 ms, SLOW2: 600 ms
Test signal level
    AC Voltage 10 mV...2 Vrms (freq. ≤ 1 MHz), 10 mV...1 Vrms (freq. > 1 MHz or freq. ≤ 1 MHz and RO=25 Ω)
    AC Current 100 µA...20 mArms (RO=100 Ω), 400 µA...40 mArms (RO=25 Ω)
    DCR Voltage 1 VDC (40 mA max.)
Measurement parameters Maximum four parameters can be measured and displayed at the same time
Impedance (Z), Inductance (Ls / Lp), Capacitance (Cs / Cp), AC Resistance (Rs / Rp), Quality Factor (Q),
Dissipation Factor (D), Admittance (Y), Conductance (G), Reactance (X), Phase Angle ( d / r), θ θ
Susceptance (B), DC Resistance (Rdc)
List measurement
    Listed steps  15
    Listed parameters  Freq/VAC/I AC/DC Bias/Comp/BIN
    Trigger  AUTO, REPEAT, SINGLE
Sweep measurement
    Swept graphical Two of measurement parameters
    Swept parameters Freq/VAC/I AC, Keep Trace
Other functions
    Auto level control (ALC) Standard
    DC Bias 0...±12 V
    Handler PASS, FAIL and OK, NG or BIN 1-9
Other features
    Correction Open/Short/HF Load/Load
    V/I monitor VAC, I AC, VDC, I DC
    Comparator Value, Δ, Δ%
    Buzzer OFF, pass, fail
    Average 1 to 64
Display 7" LCD color display (800 x 480)
Interface USB/GPIB/LAN/RS-232/Handler/USB Host/TRIGGER Input
Power source AC 100 V...240 V, 50/60 Hz / Consumption: 65 VA (max.)
Dimensions (WxHxD)
and weight
346 x 145 x 335 mm / Approx. 3.3 kg

Keywords

gw instek lcr-8200 lcr-meter
Technical information & projects
Ari Vahanen [email protected]
+358102891276

You may also need these