FLUKE II900 - Sonic Industrial Imager

Out of stock
SKU: FLUKE II900
€21,698.76 €17,499.00 Excl. Tax Incl. Tax
Contact us
Quotations, additional product information and queries about larger quantities.
Seppo Honkanen [email protected]
+358102891256
Weight 1.7 kg
Unit of measure Pcs
Product number FLUKE II900
Part number FLK-II900
Brand Name FLUKE

Espoo

In stock

In stock: 1 Pcs

Pcs
€0.00 €0.00 Excl. Tax Incl. Tax

Datasheets and attachments

Description

Fluke ii900 Sonic Industrial Imager

 

Fluke ii900 is a handheld sonic industrial imager that allows you to locate air, gas and vacuum leaks quickly and accurately. Specifically designed for noisy production facilities, the new SoundSight™ technology is easy to use.

The 7" LCD touchscreen overlays a SoundMap™ on a visual image for quick leak location identification. The straightforward, intuitive interface allows technicians to isolate the sound frequency of the leak to filter out loud background noise. In a matter of hours, the team can inspect the entire plant – during peak operations. You can quickly and easily identify air leak repairs needed to ensure efficient operations and reduce utility bills. Images can be saved and exported for reporting purposes.

Package includes:

  • Fluke ii900 imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap

For more information, see the technical specifications and datasheet.

Technical information

Technical specifications

 Sensors  
 Number of microphones  64 digital MEMS microphones
 Frequency band  2 kHz to 52 kHz
 Sound pressure   sensitivity  Detects a 0.005 CFM leak at 100PSI from up to 32.8 feet
 (Detects a 2.5 cm3/sec leak at 7 bar from up to 10  meters)
 Operation distance range  0.5 to > 50 meters (1.6 to > 164 feet)
 Field of View  65 ° ± 3 °
 Minimum frame rate  12.5 FPS
 Built-in digital camera (visible light)  
 Field of View (FOV)  65 ° ± 3 °
 Focus  Fixed lens
 Display  7" LCD with backlight, under-sunlight readable
 Resolution  1280 x 800 (1,024,000 pixels)
 Touchscreen  Capacitive
 Acoustic image  Yes, SoundMap™ image
 Image storage  
 Storage capacity  Internal memory with the capacity for 999 picture files or 20 video files
 Image format  Blended visual and SoundMap™.JPG or .PNG
 Video format  Blended visual and SoundMap™.MP4
 Video length  30 seconds
 Digital export  USB-C for data transfer
 Acoustic  Measurements  
 Measurement range  29.7 dB to 120 dB SPL at 2kHz 16 dB to 106.3 dB SPL (± 1 dB) at 19 kHz 21.4 dB to 117 dB SPL (± 1 dB) at 52 kHz
 Auto max/min dB gain  Auto or manual, user selectable
 Frequency band selection  User selectable through user-made presets or manual entry
 Software  
 Ease of use  Intuitive user interface
 Trend graphs  Frequency and dB scale
 Spot markers  dB level reading at center point of the image
 Battery  
 Batteries (field-replaceable, rechargeable)  Rechargeable Li-ion, Fluke BP291
 Battery life  ≥2 hours (product includes spare battery)
 Battery charging time  3 hours
 Battery charging system  External dual-bay charger, EDBC 290
 General specifications  
 Standard palettes  4: Grayscale, Ironbow, , Blue-Red, Gradual Blue
 Operating temperature  0 °C to +35 °C
 Storage temperature  –20 to 70 °C
 Relative humidity  10 % to 95 %, non-condensing
 Size (H x W x L)  186 mm x 322 mm x 68 mm
 Weight (battery included)  1.7 kg
 Main unit rating  IP40 protection against particles 1 mm or greater and dripping water
 Sensor head rating  IP51
 Warranty  2 years
 Self-diagnostic notification  Array-health test to identify when microphone array needs attention
 Supported languages  Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
 RoHS compliant  Yes
 General safety  IEC 61010-1
 Electromagnetic Compatibility (EMC) International  IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A
Description
Technical information

Fluke ii900 Sonic Industrial Imager

 

Fluke ii900 is a handheld sonic industrial imager that allows you to locate air, gas and vacuum leaks quickly and accurately. Specifically designed for noisy production facilities, the new SoundSight™ technology is easy to use.

The 7" LCD touchscreen overlays a SoundMap™ on a visual image for quick leak location identification. The straightforward, intuitive interface allows technicians to isolate the sound frequency of the leak to filter out loud background noise. In a matter of hours, the team can inspect the entire plant – during peak operations. You can quickly and easily identify air leak repairs needed to ensure efficient operations and reduce utility bills. Images can be saved and exported for reporting purposes.

Package includes:

  • Fluke ii900 imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap

For more information, see the technical specifications and datasheet.

Technical specifications

 Sensors  
 Number of microphones  64 digital MEMS microphones
 Frequency band  2 kHz to 52 kHz
 Sound pressure   sensitivity  Detects a 0.005 CFM leak at 100PSI from up to 32.8 feet
 (Detects a 2.5 cm3/sec leak at 7 bar from up to 10  meters)
 Operation distance range  0.5 to > 50 meters (1.6 to > 164 feet)
 Field of View  65 ° ± 3 °
 Minimum frame rate  12.5 FPS
 Built-in digital camera (visible light)  
 Field of View (FOV)  65 ° ± 3 °
 Focus  Fixed lens
 Display  7" LCD with backlight, under-sunlight readable
 Resolution  1280 x 800 (1,024,000 pixels)
 Touchscreen  Capacitive
 Acoustic image  Yes, SoundMap™ image
 Image storage  
 Storage capacity  Internal memory with the capacity for 999 picture files or 20 video files
 Image format  Blended visual and SoundMap™.JPG or .PNG
 Video format  Blended visual and SoundMap™.MP4
 Video length  30 seconds
 Digital export  USB-C for data transfer
 Acoustic  Measurements  
 Measurement range  29.7 dB to 120 dB SPL at 2kHz 16 dB to 106.3 dB SPL (± 1 dB) at 19 kHz 21.4 dB to 117 dB SPL (± 1 dB) at 52 kHz
 Auto max/min dB gain  Auto or manual, user selectable
 Frequency band selection  User selectable through user-made presets or manual entry
 Software  
 Ease of use  Intuitive user interface
 Trend graphs  Frequency and dB scale
 Spot markers  dB level reading at center point of the image
 Battery  
 Batteries (field-replaceable, rechargeable)  Rechargeable Li-ion, Fluke BP291
 Battery life  ≥2 hours (product includes spare battery)
 Battery charging time  3 hours
 Battery charging system  External dual-bay charger, EDBC 290
 General specifications  
 Standard palettes  4: Grayscale, Ironbow, , Blue-Red, Gradual Blue
 Operating temperature  0 °C to +35 °C
 Storage temperature  –20 to 70 °C
 Relative humidity  10 % to 95 %, non-condensing
 Size (H x W x L)  186 mm x 322 mm x 68 mm
 Weight (battery included)  1.7 kg
 Main unit rating  IP40 protection against particles 1 mm or greater and dripping water
 Sensor head rating  IP51
 Warranty  2 years
 Self-diagnostic notification  Array-health test to identify when microphone array needs attention
 Supported languages  Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
 RoHS compliant  Yes
 General safety  IEC 61010-1
 Electromagnetic Compatibility (EMC) International  IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A

Keywords

fluke ii900 sonic industrial imager
Contact us
Quotations, additional product information and queries about larger quantities.
Seppo Honkanen [email protected]
+358102891256

You may also need these