Rohde & Schwarz FPC-K42-03 - FPC-K42 Vector Network Analysis for FPC1500

In stock
SKU: FPC-K42-03
€930.00 €750.00 Excl. Tax Incl. Tax
Contact us
Quotations, additional product information and queries about larger quantities.
Marja Putkisaari [email protected]
+358102891209
Weight 0 g
Unit of measure pcs
Product number FPC-K42-03
Part number FPC-K42-03
Brand Name ROHDE & SCHWARZ

Vantaa

By order

Delivery time: 21 business days

pcs
€0.00 €0.00 Excl. Tax Incl. Tax
Description

Rohde & Schwarz FPC-K42 Vector network analyzer measurements (only for FPC1500)

Measurements:

  • Reflection (S11), transmission (S21)
  • 1-port cable loss
  • Distance-to-fault

Measurement setup:

Frequency range R&S FPC1500 2 MHz to 1 GHz
  with R&S FPC-B2 installed 2 MHz to 2 GHz
  with R&S FPC-B2 and FPC-B3 installed 2 MHz to 3 GHz
Port output power   -10 dBm (nom.)
Data points selectable 101 to 2501
Measurement bandwidth   100 Hz to 100 kHz in 1/3 sequence
Trace modes   clear/write, average

Transmission measurement S21:

Result formats magnitude
Magnitude  
  Range 1/2/5/10/20/50/100/120/150 dB, linear 100 %
  Resolution 0.1 dB
  Dynamic range 80 dB (nom.)

Reflection measurement S11:

Result formats   magnitude, VSWR, distance-to-fault, Smith chart, phase
Magnitude
Resolution   0.1 dB
Range   1/2/5/10/20/50/100/120/150 dB, linear 100 %
VSWR
Range selectable 1 to 1.5, 2, 6, 11, 21 or 71
Measurement speed   0.3 ms per point
Corrected test port match with R&S ZN-Z103 2 MHz ≤ f ≤ 3 GHz >42 dB (nom.)
Measurement uncertainty with R&S ZN-Z103 2 MHz ≤ f ≤ 3 GHz >36 dB (nom.)
1-port cable loss measurement    
Result format   magnitude
Range   1/2/5/10/20/50/100/120/150 dB
Resolution   0.1 dB

Distance-to-fault analysis

Result formats   return loss, VSWR with average and maximum indication
Return loss
   Range   1/2/5/10/20/50/100/120/150 dB, linear 100 %
   Resolution   0.1 dB
VSWR
   Range selectable 1 to 1.5, 2, 6, 11, 21 or 71
Fault resolution in meters   (1.5 x 108 x velocity factor/span)
Maximum cable length depending on cable loss 1500 m (nom.)
Immunity to interference
Maximum permissible spurious signal measurement = reflection (S11)/1 - port cable loss/distance-to-fault analysis
  +17 dBm (nom.)
Description

Rohde & Schwarz FPC-K42 Vector network analyzer measurements (only for FPC1500)

Measurements:

  • Reflection (S11), transmission (S21)
  • 1-port cable loss
  • Distance-to-fault

Measurement setup:

Frequency range R&S FPC1500 2 MHz to 1 GHz
  with R&S FPC-B2 installed 2 MHz to 2 GHz
  with R&S FPC-B2 and FPC-B3 installed 2 MHz to 3 GHz
Port output power   -10 dBm (nom.)
Data points selectable 101 to 2501
Measurement bandwidth   100 Hz to 100 kHz in 1/3 sequence
Trace modes   clear/write, average

Transmission measurement S21:

Result formats magnitude
Magnitude  
  Range 1/2/5/10/20/50/100/120/150 dB, linear 100 %
  Resolution 0.1 dB
  Dynamic range 80 dB (nom.)

Reflection measurement S11:

Result formats   magnitude, VSWR, distance-to-fault, Smith chart, phase
Magnitude
Resolution   0.1 dB
Range   1/2/5/10/20/50/100/120/150 dB, linear 100 %
VSWR
Range selectable 1 to 1.5, 2, 6, 11, 21 or 71
Measurement speed   0.3 ms per point
Corrected test port match with R&S ZN-Z103 2 MHz ≤ f ≤ 3 GHz >42 dB (nom.)
Measurement uncertainty with R&S ZN-Z103 2 MHz ≤ f ≤ 3 GHz >36 dB (nom.)
1-port cable loss measurement    
Result format   magnitude
Range   1/2/5/10/20/50/100/120/150 dB
Resolution   0.1 dB

Distance-to-fault analysis

Result formats   return loss, VSWR with average and maximum indication
Return loss
   Range   1/2/5/10/20/50/100/120/150 dB, linear 100 %
   Resolution   0.1 dB
VSWR
   Range selectable 1 to 1.5, 2, 6, 11, 21 or 71
Fault resolution in meters   (1.5 x 108 x velocity factor/span)
Maximum cable length depending on cable loss 1500 m (nom.)
Immunity to interference
Maximum permissible spurious signal measurement = reflection (S11)/1 - port cable loss/distance-to-fault analysis