FLUKE 1748/15 - POWER QUALITY LOGGER W/1500A IFLEX
Contact us
Orders & inquiries
[email protected]Technical information & projects
Seppo Honkanen [email protected]Weight | 4.14 kg |
---|---|
Unit of measure | pcs |
Product number | FLUKE 1748/15 |
Part number | FLUKE 1748/15/EUS |
Brand Name | FLUKE |
Vantaa
By order
Delivery time: 21 business days
Fluke 1748/15 Three-phase power quality logger with 1,500A iFlex current probes
The Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers give you fast, easy access to the data you need to make critical power quality and energy decisions in real-time. Compact and rugged, the Fluke 1740 Series Three-Phase Power Quality Loggers are designed specifically for technicians and engineers who need the flexibility to troubleshoot, quantify energy usage and analyze power distribution systems.
The Fluke 1746 can be upgraded to 1748. The Fluke 1742 can be upgraded to 1746, or complete 1748, functionality.
The right model for you:
Recording | 1742 | 1746 | 1748 |
Energy | • | • | • |
Basic Power Quality | Optional | • | • |
Advanced Power Quality | Optional | Optional | • |
Features:
- Measure all three voltage and current phases plus the neutral current.
- More than 20 separate logging sessions can be automatically stored in the instrument.
- Meets the rigorous IEC 6100-4-30 Class A Edition 3 standard for testing and measurement techniques.
- Capture dips, swells and interruptions.
- Measure key power quality parameters: Measures harmonics and inteharmonics for voltage and current, also includes unbalance, flicker and rapid voltage changes.
- Optimized user interface: Capture the right data every time with quick, guided, graphical PC based application setup and reduce uncertainty about your connections with an intelligent verification feature and the only auto-correction function for a power quality logger.
- Flexible power supply: Powers directly from the measured circuit with the widest available range for a power quality logger automatically going from 100 V to 500 V or from a wall line cord, so you can test anywhere.
- Rugged and reliable, IP65 rating when used with IP65 voltage input adapter.
- Two external USB ports: One for PC connection and another for quick, simple data download to standard USB thumb drives or other USB devices.
- Ethernet connectivity: Wired and wireless connections for instrument setup and high-speed data download.
- Compact size: designed to fit in tight spaces with small 23 cm x 18 cm x 5.4 cm footprint.
- Highest safety rating in the industry: 600 V CAT IV / 1000 V CAT III rated for use at the service entrance and downstream.
- Optimized measurement accessories: Unique tangle-free flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.
- Security: Safeguard your best asset from theft with a standard chain or other security devices.
- Magnetic hanger kit: Conveniently stow the instrument safety inside or outside of electrical panels (standard in model 1748).
Software features:
- "In-workshop" or "in-the-field" setup and download through PC application software: simple download using USB memory stick, WiFi download, wired ethernet connection or via USB cable.
- Energy Analyze plus application software: Download and analyze every measured detail of energy consumption and power quality state-of-health with automated reporting.
- One-touch reporting: Create standardized reports according to commonly used standards like EN 50160, IEEE 519, GOST 33073 or export data in PQDIF or NeQual compatible format for use with third party software.
- Advanced analysis: Choose any available logged parameter to create a highly customized view of logged measurements for advanced correlation of data.
Features: |
FLUKE 1742 |
FLUKE 1746 |
FLUKE 1748 |
Functions: | |||
Voltage, current, power, power factor, frequency | • | • | • |
Energy forward/reverse | • | • | • |
Peak demand | • | • | • |
THD | • | • | • |
Flicker | • | • | • |
Voltage and current harmonics (to 50th) | • | • | |
Unbalance | • | • | |
Rapid voltage change events | • | • | |
Interharmonics (to 50th) | • | • | |
Dips, swells, interruption and transient events tables | • | • | |
Inrush current | • | • | |
Transients (low frequency) / waveform deviation events | • | ||
Recording: | |||
Trend | • | • | • |
Waveform snapshots | • | ||
RMS profile | • | ||
Communication: | |||
Ethernet | • | • | • |
USB (mini-B) | • | • | • |
WiFi download instrument to device | • | • | • |
WiFi download via WiFi hub (requires registration) | Optional | Optional | Optional |
Flexible current probe
|
Fluke i17xx-Flex 1,500A |
Measuring ranges |
1-150 A AC 10-1500 A AC |
Probe cable length | 610 mm |
Probe cable diameter | 7.5 mm |
Weight | 170 g |
Minimum bending radius | 38 mm |
Nondestructive current | 100 kA (50/60 Hz) |
Temperature coefficient over operating temperature range |
0.005 % of reading / °C |
Working voltage | 1000 V CAT III, 600 V CAT IV |
Output cable length | 2.0 m |
Probe cable material | TPR |
Coupling material | POM + ABS/PC |
Output cable | TPR/PVC |
Operating temperature | -20 to +70 °C temperature of conductor under test shall not exceed 80 °C |
Temperature, non-operating | -40 to +80 °C |
Relative humidity, operating | 15-85 % non-condensing |
IP rating | IEC 60529: IP65 |
Included accessories:
- Flexible current probe (not /B version)
- USB stick
- USB cable
- 3PHVL-1730 3-phase and neutral voltage test lead
- Test lead set red/black 0.18 m
- Test lead set red/black 1.5 m
- Alligator clips 4 pcs
- Soft case
- Cable marker kit
- MP1-3R/1B-Magnet probe 1 set (3 red, 1 black) (not 1742)
- 174x-Hanger Kit (not 1742 and 1746)
For more information see the datasheets.
Fluke 1748/15 Three-phase power quality logger with 1,500A iFlex current probes
The Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers give you fast, easy access to the data you need to make critical power quality and energy decisions in real-time. Compact and rugged, the Fluke 1740 Series Three-Phase Power Quality Loggers are designed specifically for technicians and engineers who need the flexibility to troubleshoot, quantify energy usage and analyze power distribution systems.
The Fluke 1746 can be upgraded to 1748. The Fluke 1742 can be upgraded to 1746, or complete 1748, functionality.
The right model for you:
Recording | 1742 | 1746 | 1748 |
Energy | • | • | • |
Basic Power Quality | Optional | • | • |
Advanced Power Quality | Optional | Optional | • |
Features:
- Measure all three voltage and current phases plus the neutral current.
- More than 20 separate logging sessions can be automatically stored in the instrument.
- Meets the rigorous IEC 6100-4-30 Class A Edition 3 standard for testing and measurement techniques.
- Capture dips, swells and interruptions.
- Measure key power quality parameters: Measures harmonics and inteharmonics for voltage and current, also includes unbalance, flicker and rapid voltage changes.
- Optimized user interface: Capture the right data every time with quick, guided, graphical PC based application setup and reduce uncertainty about your connections with an intelligent verification feature and the only auto-correction function for a power quality logger.
- Flexible power supply: Powers directly from the measured circuit with the widest available range for a power quality logger automatically going from 100 V to 500 V or from a wall line cord, so you can test anywhere.
- Rugged and reliable, IP65 rating when used with IP65 voltage input adapter.
- Two external USB ports: One for PC connection and another for quick, simple data download to standard USB thumb drives or other USB devices.
- Ethernet connectivity: Wired and wireless connections for instrument setup and high-speed data download.
- Compact size: designed to fit in tight spaces with small 23 cm x 18 cm x 5.4 cm footprint.
- Highest safety rating in the industry: 600 V CAT IV / 1000 V CAT III rated for use at the service entrance and downstream.
- Optimized measurement accessories: Unique tangle-free flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.
- Security: Safeguard your best asset from theft with a standard chain or other security devices.
- Magnetic hanger kit: Conveniently stow the instrument safety inside or outside of electrical panels (standard in model 1748).
Software features:
- "In-workshop" or "in-the-field" setup and download through PC application software: simple download using USB memory stick, WiFi download, wired ethernet connection or via USB cable.
- Energy Analyze plus application software: Download and analyze every measured detail of energy consumption and power quality state-of-health with automated reporting.
- One-touch reporting: Create standardized reports according to commonly used standards like EN 50160, IEEE 519, GOST 33073 or export data in PQDIF or NeQual compatible format for use with third party software.
- Advanced analysis: Choose any available logged parameter to create a highly customized view of logged measurements for advanced correlation of data.
Features: |
FLUKE 1742 |
FLUKE 1746 |
FLUKE 1748 |
Functions: | |||
Voltage, current, power, power factor, frequency | • | • | • |
Energy forward/reverse | • | • | • |
Peak demand | • | • | • |
THD | • | • | • |
Flicker | • | • | • |
Voltage and current harmonics (to 50th) | • | • | |
Unbalance | • | • | |
Rapid voltage change events | • | • | |
Interharmonics (to 50th) | • | • | |
Dips, swells, interruption and transient events tables | • | • | |
Inrush current | • | • | |
Transients (low frequency) / waveform deviation events | • | ||
Recording: | |||
Trend | • | • | • |
Waveform snapshots | • | ||
RMS profile | • | ||
Communication: | |||
Ethernet | • | • | • |
USB (mini-B) | • | • | • |
WiFi download instrument to device | • | • | • |
WiFi download via WiFi hub (requires registration) | Optional | Optional | Optional |
Flexible current probe
|
Fluke i17xx-Flex 1,500A |
Measuring ranges |
1-150 A AC 10-1500 A AC |
Probe cable length | 610 mm |
Probe cable diameter | 7.5 mm |
Weight | 170 g |
Minimum bending radius | 38 mm |
Nondestructive current | 100 kA (50/60 Hz) |
Temperature coefficient over operating temperature range |
0.005 % of reading / °C |
Working voltage | 1000 V CAT III, 600 V CAT IV |
Output cable length | 2.0 m |
Probe cable material | TPR |
Coupling material | POM + ABS/PC |
Output cable | TPR/PVC |
Operating temperature | -20 to +70 °C temperature of conductor under test shall not exceed 80 °C |
Temperature, non-operating | -40 to +80 °C |
Relative humidity, operating | 15-85 % non-condensing |
IP rating | IEC 60529: IP65 |
Included accessories:
- Flexible current probe (not /B version)
- USB stick
- USB cable
- 3PHVL-1730 3-phase and neutral voltage test lead
- Test lead set red/black 0.18 m
- Test lead set red/black 1.5 m
- Alligator clips 4 pcs
- Soft case
- Cable marker kit
- MP1-3R/1B-Magnet probe 1 set (3 red, 1 black) (not 1742)
- 174x-Hanger Kit (not 1742 and 1746)
For more information see the datasheets.